Filter Results By:

Products

Applications

Manufacturers

Showing results: 496 - 510 of 595 items found.

  • Connector Test

    Applied Relay Testing Ltd.

    A connector test system which provides expansion of up to 160 Kelvin pair connections. The system incorporates high voltage AC and DC power supplies with a maximum output of +/- 2100 Volts peak for Hi Pot, Insulation resistance measurement. LCR bridge control is provided with 4 terminal multiplexing in order to add precision capacitance, inductance and resistance measurement capability. An integral H.V. capacitor bias option permits capacitance measurement to be made at up to 2.1kV.

  • Wide Range High Voltage Programmable DC Power Supply

    N3600 Series - Next Generation Instrumental (Shanghai) T&C Tech. Co., Ltd.

    N3600 series is developed based on NGI's years of experience in testing for battery fluctuation simulation test, battery charger, high voltage diode, electrolytic capacitor, electromechanical control, ATE test system, etc. It is a high-voltage wide-range programmable DC power supply. According to different test environments in the fields of lab test, system integration test, and mass production line, NGI has made a number of optimization designs based on the international advanced technology. N3600 series is a market leader in similar products in terms of reliability, maintainability and safety.

  • AC Hipot Tester /DC Hipot Tester

    YD-Series - Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd

    YD series HIPOT tester is applied to test the insulation ability of electric power equipments and insulation materials at power frequency high voltage. The insulation test result of the tester is go or not go. Also the YD series HIPOT tester is a universal power source in HV test. The maximum output voltage and capacity could be customized according the requirements of custom.The tester is consists of single HV transformer and main control box. There are two kinds of HV transformer according to the insulation materials of the HV transformer.They are dry HV transformer and oil HV transformer. For the dry HV transformer the insulation material is epoxy resin.For oil HV transformer the insulation material is insulation oil. The dry HV transformer has a smaller size and less weight than oil HV transformer. But the maximum output voltage is less than 100kv for dry HV transformer. The functions of the main control box are voltage output regulation, protection in emergency and voltage/current value indication

  • THREE PHASE PORTABLE ENERGY METER CALIBRATION EQUIPMENT

    GF302D1 - Beijing GFUVE Electronics Co.,Ltd.

    The GF302D1 three phase portable energy meter test system consists of an integrated three phase current and voltage source(up to 500V/120A or 500V/20A) and built-in three-phase electronic reference standard of accuracy class 0.05%. Characteristic features of the GF302D1 are its wide measuring range, high accuracy and high tolerance to unwanted external influences. The equipment offers high functionality combined with an excellent menu guided operation via built-in keyboards and colored 7" touch LCD-display.

  • Digital Insulation Tester - Compact Insulation Resistance Tester with Snap-On Protective Cover

    Extech MG310 - Extech Instruments Corporation

    The MG310 is a Compact Insulation Resistance Tester which allows quick and easy testing/troubleshooting of motors, transducers, and other industrial appliances. Wide range measurement up to 1000V with Insulation Resistance to 5.5GΩ. Includes an easy snap on protective hard cover and soft pouch to conveniently transport your meter and accessories to the next job site or to safely store away. Featuring Low Resistance measurement with Zero function, Continuity beeper, Large 2000 count dual display with backlight, High voltage and overload indication, Auto-discharge and voltage output warning functions as well as Low battery indication. Complete with test leads, alligator clips, 6 x AA batteries, hard cover, and soft carrying case.

  • Electrical Fast Transient Pulse Group Generator

    SKS-0404IB - Shanghai Sanki Electronic Industries Co., Ltd.

    Electrical fast transient pulse group generator SKS-0404IB fully complies with the new standards of IEC61000-4-4, EN61000-4-4 and GB/T17626.4; provides pulse test voltage up to 4500V, which can meet various product standards Severity level ; pulse frequency up to 1MHz, and continuously adjustable; imported discharge switch, high precision, long life, good reproducibility; using 7-inch true color touch screen control, convenient for users to directly program and control.

  • Generator Insulation Resistance Tester

    WA2660 - Wuhan Sangao Electrical Test Installations Limit Co.

    WA2660 series insulation resistance testing instrument is special use for internal water cooling generator's measurement test. Meanwhile, can also be used in laboratory or field insulation test.The output current is greater than 25mA,Maximum output voltage is 2500V.With high precision micro current measurement system, digital boost system.Only need a high-voltage line and a signal line connecting the sample can be measured.Automatic measurement, the results from the large screen liquid crystal display, and the results are stored.

  • Highly Inductive Resistance Meter

    MR 8050 - Schuetz Messtechnik GmbH

    With the MR 8050 resistances highly inductive Resistance Meters windings of transformers, motors and reactors can be measured. (range 100 µΩ with 0.01µΩ resolution up to 6 kΩ). The performance of the test objects can be up to 800 MVA or even more. The magnetic loading of a transformer is performed quickly using a high loading voltage (60V). This is important for time critical measurements (cooling curves). The unloading of the transformers core is very fast, very safe, as the energy is total destroyed in the MR 8050.

  • MCB Magnetic (Instantaneous) Trip Test Bench

    SCR ELEKTRONIKS

    The test bench is specially built for low voltage- B, C & D curve MCBs. Specially designed custom built jigs are able to accommodate single, double, three and four pole MCBs. Decades of experience has helped us to design current source (transformer) in a special way such that good current regulation and high accuracy is ensured with a variable range without the use of any variable transformer in the system. The product is better than the competition with conventional technology at a lesser price!

  • Modular DC Electronic Load

    N3300A Series - Keysight Technologies

    The new N3300A Series of dc electronic loads is fast, accurate, and ideal for increasing production throughput in high volume dc power supply manufacturing. This series consists of a full rack width (1800 watts max) mainframe and a half rack width (600 watts max) mainframe, and 7 interchangeable electronic load modules. The modules provide a variety of voltage, current and power ratings. New dc connectors for test system configurations are now available on all modules.

  • 903 Benchtop Three Phase 40A

    Weshine Electric Manufacturing Co., Ltd

    1. The instrument has standard four phase voltage and three-phase current output. It can test not only various traditional relays and protection devices, but also various modern microcomputer protections, especially for transformer differential protection and standby automatic switching device. The test is more convenient and perfect.2. Classic Windows XP operation interface, friendly man-machine interface, easy and fast operation; high performance embedded industrial control computer and 8.4 inch resolution 800 × 600 TFT true color display screen, can provide rich and intuitive information, including the current working state of the equipment and various help information.

  • Power/Voltage Rail Probe. 4 GHz Bandwidth, 1.2x Attenuation, +/-30V Offset, +/-800mV

    RP4030 - Teledyne LeCroy

    The Teledyne LeCroy RP4030 Power Rail Probe meets the specific requirements of those who need to acquire a low-voltage DC signal as part of a:-Comprehensive power integrity, digital power management IC (PMIC), voltage regulator module (VMR), point-of-load (POL) switching regulator, or low-dropout regulator testing- Complete embedded power management system that includes PMICs, VRMs, POLs, and LDOsThe RP4030 will faithfully acquire a low-impedance, low-voltage DC power/voltage rail signal without unduly loading the device under test (DUT), while providing high offset to allow DC power/voltage rail signal display on an oscilloscope with high gain.

  • 12V Automatic Battery and 12/24V Electrical System Analyzer

    6044 - Associated Equipment Corp.

    • Easy-to-read LED voltmeter and ammeter• 500 amp safety clamps with “Flexi-Spring” and patented side terminal adapters• Separate 6 ft. high impedance test leads with alligator clips for tight spots• Cart / Printer can be purchased separately – Cart Model 6038C, Printer Model 6041• Automated testing of Batteries, Alternators, & Starters• Max/Min of Current and Voltage• Microprocessor based control board protected from reverse connections• Testing of 12V and 24V electrical systems• Test all types of batteries • Ideal for testing remotely mounted batteries accurately• Automated 500A variable load tester• INCLUDES: Model 6043 1000 Amp AC/DC Inductive Amp Clamp for checking starter draw or parasitic drain test, also can be used with conventional multi-meters• Made in USA of US and Global Components

  • Track-Signal Test Meter

    Model TRSIG-1 - Aplab Limited

    Aplab Track-Signal Test Meter incorporates Digital Signal Processing based design to provide high accuracy and stability. It is designed for level measurement of selected frequencies. It also provides functionality of AC and DC voltage measurements.The purpose of Track-Signal Test Meter is to make adjustments, control measurements and inspections on both audio frequency track circuits of types FTGS 46, FTGS 917 and also for TI21M type track circuits (now known as BI track 300) for the measurement of eight frequencies from 5700Hz to 8500Hz for metro applications. Its compactness and battery operation render the unit particularly suitable for portable applications in maintenance and for level measurement in communication systems.

  • VFTLP+ Test System

    4012 - Barth Electronics, Inc

    The Model 4012 VFTLP+™ test system was developed in early 2000 to add high speed measurements to the usual I-V plot, to measure and record the real TDDB waveform which causes oxide failure.*Accurate measurements of this waveform have finally been identified by Barth Electronics Inc. and CDM protection can now be based on known dimensional design parameters. We identify the response of your CDM protection circuits with 100ps risetime pulses which simulate the real CDM test. This is the only way with which to provide the total gate oxide threat voltage data.*Convenient, precise, repeatable operation*Computer controlled for automated testing

Get Help